Ashtech Z-sensor Especificações Página 112

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 111
92 Z-Family Technical Reference Manual
MDM: Set Modem Parameters
$PASHS,MDM,s1,c2,d3,d4,CFG,s5,MOD,s6,NAM,s7,D2C,s8,C2D,s9
All s-Parameter optional settings are user defined modem settings and can be entered in any order
and with any combination of these settings. If the baud rate index code in not entered, the default
baud rate (7=38400) will be used.
Table 6.19: MDM Setting Parameters and Descriptions
Setting Parameter Description Range Default
s1 Switch to set modem in use flag on or off “ON”/”OFF” Off
c2 Serial port that modem connect to ‘A’- ‘D’ B
d3 Modem type index:
0 - US Robotics Sportster
1 - Telebit WorldBlazer
2 - Telebit TrailBlazer
3 - Telebit CellBlazer
4 - User defined
0 - 4 0
d4 [optional] Baud Rate Index Code 3 - 8 7
CFG,s5 [optional] Modem configuration initialization string 96 bytes
MOD,s6 [optional] Modem Configuration mode used 16 bytes
NAM,s7 [optional] Modem name 40 bytes
D2C,s8 [optional] Data to command mode escape string 16 bytes
C2D,s9 [optional] Command to data mode string 16 bytes
Table 6.20: Baud Rate Codes
Code Baud Rate Code Baud Rate
0 300 5 9600
1 600 6 19200
2 1200 7 38400
3 2400 8 57600
4 4800 9 115200